Previous  Next          Contents  Index  Navigation  Glossary  Library

Defining Collection Element Specification Limits

You can define specification limits for collection elements of any collection element or datatype. However specification limits -- which include a target value and three sets of upper and lower range limits -- are normally associated with numeric collection elements. Specification limits can be changed without restriction.

You can create specification elements by adding collection elements to your specifications. Collection element specification limits are defaulted to these specification elements. For example, if you create a specification element by adding the Frequency collection element to a specification, the target value of 2000, and lower and upper user-defined, specification, and reasonable range limits -- 1800-2200, 1720-2080, and 1600-2400 respectively -- are defaulted to the specification element.

Attention: If you are defining specification limits for numeric collection elements, the decimal precision of the collection element controls the decimal precision of the specification limits. For example, if the decimal precision of the collection element is 3, you can define specification limits of up to 3 decimal places such as 3.999.

   To define collection element specification limits:


         Previous  Next          Contents  Index  Navigation  Glossary  Library